Heating a rental: the heating standard and running costs

Guide · written 20 Nov 2026

Auckland winters are mild by national standards, but a cold, damp rental is still one of the most common complaints tenants raise. Since the healthy homes standards came in, landlords have had a defined minimum for heating. This article explains that minimum, then turns to the question tenants usually care about more: what it costs to run the heater once it is on the wall.

The details here follow Tenancy Services' heating standard page at the time of writing. Check it for any changes.

What the standard requires

In plain terms, a rental needs one or more fixed heaters that can directly heat the main living room. The main living room is the largest room used for everyday living, such as a lounge, family room or dining room. The heaters must be fixed rather than portable and must be at least 1.5 kW.

They also have to meet a minimum heating capacity for the room. The capacity depends on things like the room's size, ceiling height and how much heat it loses through its windows and walls. Tenancy Services provides a heating assessment tool to calculate it, and the formula in the regulations or a professional assessment can also be used.

Which heaters count

Tenancy Services says the usual qualifying options are a heat pump, a woodburner, a pellet burner or a flued gas heater. In some small apartments a smaller heater may be enough. Central heating counts if it heats the main living room directly and meets the capacity.

Some details worth knowing:

  • Heat pumps and electric heaters must have a thermostat.
  • A fixed electric heater other than a heat pump cannot be used where the required capacity is over 2.4 kW, with an exception for topping up existing heating installed before 1 July 2019.
  • Open fires and unflued combustion heaters, such as portable LPG bottle heaters, do not qualify.
  • Existing heating installed before 1 July 2019 can count if each heater is over 2.4 kW and the total is at least 80 percent of the required capacity.

Exemptions are narrow. They cover cases where installing a qualifying heater is not reasonably practicable, for example because it would need substantial building work, and certified passive buildings. Landlords who do not own the whole building may be partly exempt but must still install at least one qualifying heater of 2 kW or more. Tenancy Services lists penalties of up to $7,200 for breaches.

What this means for tenants

If your living room has only a portable electric heater or an open fire, and you rent from a landlord who is subject to the standard, you may have grounds to raise it. Start with a polite written request, quoting the page above. If nothing happens, the process is a 14-day notice to remedy the breach and then the Tenancy Tribunal, as set out in Tenancy Services' guidance on breaches.

Two things the standard does not do: it does not require heating in every room, and it does not set a rule about how much heat you must use. Bedrooms are your own business.

Running costs: what drives the bill

Tenancy Services does not publish running costs, and prices vary between retailers and plans, so this article avoids quoting a per-hour figure. What you can do is work out your own.

The basic arithmetic is simple. A heater's power rating in kilowatts, multiplied by the hours it runs, gives kilowatt-hours used. Multiply that by the unit price on your electricity plan and you have the cost. A 2 kW heater that runs for five hours uses 10 kWh; your bill depends on what your retailer charges per kWh.

Heat pumps are generally cheaper per unit of heat than resistance heaters, because they move heat rather than create it. Under the standard they are also the only fixed electric option where the required capacity is over 2.4 kW. If the landlord has installed one, using it with the thermostat set sensibly is usually the economical way to meet your own comfort needs.

Keeping the cost down

  • Heat steadily rather than in bursts. Consumer NZ's moisture guidance suggests keeping low levels of heat on most of the time, and aiming for an indoor temperature at least 7°C above the outdoor temperature to limit condensation.
  • Use the thermostat. The standard requires one on electric heaters and heat pumps; set it rather than running flat out.
  • Close the room you are heating. Shut doors and draw curtains at dusk so the heat stays where you are sitting.
  • Stop the draughts. Consumer NZ suggests seal tape around windows and doors. It is cheap, but ask the landlord first if it might mark the frames.
  • Compare plans. Powerswitch, run by Consumer NZ, compares electricity plans at your address. Our guide to setting up utilities covers when to do that.
  • Avoid portable gas heaters. They release water vapour as they burn, which feeds condensation and mould. See winter in a cold rental.

If the heater is the landlord's, who fixes it?

A fixed heater provided under the standard is part of the property, so the landlord is responsible for keeping it in working order. Tell them in writing if it breaks, and keep a copy. If you damage it carelessly, the usual damage rules apply.

This is general information and not legal advice.